October 3, 2018

Geothermal Cooling and Heating Concept Explained

Outdoor temperatures fluctuate with the changing seasons but underground temperatures don’t change as dramatically, thanks to the insulating properties of the earth. Four to six feet below ground, temperatures remain relatively constant year-round. A geothermal system, which typically consists of an indoor handling unit and a buried system of pipes, called an earth loop, and/or a pump to re-injection well, capitalizes on these constant temperatures to provide “free” energy.

(Note that geothermal HVAC should not be confused with “geothermal energy,” the process by which electricity is generated directly from the heat inside the earth. That takes place on the scale of utilities and uses different processes, normally by heating water to boiling.)

The pipes that make up an earth loop are usually made of polyethylene and can be buried under the ground horizontally or vertically, depending on the characteristics of the site. If an aquifer is available, engineers may prefer to design an “open loop” system, in which a well is drilled into the underground water. Water is pumped up, run past a heat exchanger, and then the water is returned to the same aquifer, through “re-injection.”

In winter, fluid circulating through the system’s earth loop or well absorbs stored heat from the ground and carries it indoors. The indoor unit compresses the heat to a higher temperature and distributes it throughout the building, as if it were an air conditioner running in reverse. In summer, the geothermal HVAC system pulls heat from the building and carries it through the earth loop/pump to re-injection well, where it deposits the heat into the cooler earth/aquifer.

Unlike ordinary heating and cooling systems, geothermal HVAC systems do not burn fossil fuel to generate heat; they simply transfer heat to and from the earth. Typically, electric power is used only to operate the unit’s fan, compressor, and pump.

A geothermal cooling and heating system has three main components: the heat-pump unit, the liquid heat-exchange medium (open or closed loop), and the air-delivery system (duct-work) and/or the radiant heating (in the floor or elsewhere).

Geothermal heat pumps, as well as all other types of heat pumps, have efficiencies rated according to their coefficient of performance, or COP. It’s a scientific way of determining how much energy the system moves versus how much it uses. Most geothermal heat pump systems have COPs of 3.0 to 5.0. This means for every unit of energy used to power the system, three to five units are supplied as heat.

Geothermal systems require little maintenance. When installed properly, which is critical, the buried loop can last for generations. The unit’s fan, compressor, and pump are housed indoors, protected from the harsh weather conditions, so they tend to last for many years, often decades. Usually, periodic checks and filter changes and annual coil cleaning are the only required maintenance.

Additional information can be found at 10 Myths About Geothermal Heating and Cooling.